Like the great French general, the Valcourt team has been able to use its tactical skills to upgrade this non-catalytic unit, so that it perfectly combines the new heating technology with all its elegance.
Customize your fireplace: five faceplate louvers as well as black or brushed nickel door overlays are available to enhance your decor. In addition to offering a distinctive look, the appliance follows the most restrictive EPA regulations, making it the fireplace of choice for those who want to use wood as a renewable and clean source of heat.
Heating area :
<1000 ft2
Maximum heat output :
80,000 BTU/h (23.4 kW)
Efficiency
Door
Single
*NOTE:The faceplate, faceplate louver and door overlaymust be purchased to complete this unit.
Appliance Performance
Fuel type :
Dry cordwood (16" recommended)
Recommended heating area-ft² :()
750 - 2,200
Overall firebox volume-ft³ :
2.5
EPA loading volume-ft³ :
1.94
Maximum burn time :()
8 h
Maximum heat output-dry cordwood :(2)
80,000 BTU/h (23.4 kW)
Overall heat output rate < :(2)(3)
12,700 BTU/h (3.72 kW) to 60,700 BTU/h (17.79 kW)
Average overall efficiency (dry cordwood) :(3)
64% (HHV)(4)
68% (LHV)(5)
Optimum efficiency :(6)(7)
70%
Optimum heat transfer efficiency :(8)
68%
Average particulate emissions rate :(9)
1.2 g/h
Average CO :(10)
98 g/h
(1)Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
()Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(2)The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(3)As measured per CSA B415.1-10 stack loss method.
(4)Higher Heating Value of the fuel.
(5)Lower Heating Value of the fuel.
(6)Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(7)Optimum overall efficiency at a specific burn rate (LHV).
(8)The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(9)This appliance is officially tested and certified by an independent agency.
(10)Carbon monoxyde.
Approved Chimney Types
Manufacturiers*
Brand
Type
Diameter
American Metal
HSS
AC Triple Wall
6" (15 cm)
American Metal
HS
AC Triple Wall
6" (15 cm)
DuraVent
DuraTech
1" Solid Pack
6" (15 cm)
DuraVent
DuraTech Canada (DTC)
1" Solid Pack
6" (15 cm)
DuraVent
DuraPlus HTC
2" Solid Pack
6" (15 cm)
DuraVent
DuraTech Premium
2" Solid Pack
6" (15 cm)
DuraVent
DuraPlus
AC Triple Wall
6" (15 cm)
Metal Fab
Temp Guard
1" Solid Pack
6" (15 cm)
Olympia Chimney
Champion Chimney System
1" Solid Pack
6" (15 cm)
Olympia Chimney
Rockford Chimney Systems
1" Solid Pack
6" (15 cm)
Olympia Chimney/SBI Venting Division
Olympia Chimney/SBI Venting Division
1" Solid Pack
6" (15 cm)
SBI Venting Division
Nexvent
1" Solid Pack
6" (15 cm)
Security Chimney
S-2100+
2" Solid Pack
6" (15 cm)
Selkirk
CF Sentinel (CF)
2" Solid Pack
6" (15 cm)
Selkirk
Super Pro 2100 (ALT)
2" Solid Pack
6" (15 cm)
Selkirk
Super Vent 2100 (JM)
2" Solid Pack
6" (15 cm)
* Specific components may be required depending on the chimney manufacturer.
Minimum clearances to combustibles* (Data expressed in inches. 1 inch = 25.4 mm)
Canada
United-States
Clearance – top (measured from the platform on which the appliance is installed)**
80"
80"
Clearance – combustible side mantle to unit
8"
8"
Clearance – combustible side wall to unit
13"
13"
Clearance - from the shelf to the base of the fireplace
58"
58"
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
Features
Model No.:
FP10RS
Combustion technology
Non-catalytic
High-efficiency certified appliance
Yes, EPA 2020 approved
Maximum log length
20"
Log positioning
Loading over width
Chimney diameter
6"
Flue outlet diameter
6"
Type of chimney:
CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet)
15'
Baffle type
C-Cast or equivalent
Approved for a mobile home installation
No
Shipping Weight
495 lb (225 kg)
Door type
Single, glass with steel frame
Glass type
Ceramic glass
Glass surface – dimensions (Width X Height)
23 7/8" X 10 1/2"
Glass air-wash system
Yes
Premium quality blower included (CFM)
176
Overall dimension (Height)
40 5/8"
Overall dimension (Width)
36 3/4"
Overall dimension (Depth)
28 5/8"
Door opening – dimension (Height)
10 1/2"
Door opening - dimension (Width)
25 3/8"
Firebox – dimension (Height)
12 1/8"
Firebox – dimension (Width)
20 3/8"
Firebox – dimension (Depth)
13"
Moulded refractory bricks
Yes
Stainless-steel secondary-air system improving gas combustion