Call NowGet up to $200 OFF when you call!
Ends in 10:00
Customer Reviews
John D. "Great service! Highly recommend."
Jane S. "Saved $50 on my order."
Mike T. "Fast and reliable support."
Description
Shipping & Returns Policy
Request A Quote
Description
SPRSUN R32 ClimaPro Series - 6KW/9.5KW/12KW/16KW EVI DC Inverter Air to Water Heat Pumps - Monoblock Type
If you are looking for a highly efficient and environmentally friendly heating solution, the SPRSUN R32 ClimaPro Series - 6KW/9.5KW/12KW/16KW EVI DC Inverter Air to Water Heat Pumps - Monoblock Type is the perfect choice for your home or business. With a wide operating range from -25°C to 45°C, this heat pump provides reliable heating and cooling in even the most extreme climates. Whether you need 6KW, 9.5KW, 12KW, or 16KW of heating power, the SPRSUN R32 ClimaPro Series ensures that your space is consistently comfortable, all year round.
Designed with the environment in mind, this air-to-water heat pump uses R32 refrigerant, which significantly reduces the impact on the planet. In addition to its eco-friendly design, it offers impressive energy efficiency with an ERP A+++ rating and a COP of 5.56. The SPRSUN R32 ClimaPro Series operates on both 220V-240V or 380V-420V power supply, making it adaptable to various residential and commercial setups. Its DC inverter technology enhances the circulation of fluids, boosting overall system performance and lowering energy consumption.
By investing in the SPRSUN R32 ClimaPro Series, you’re not only enhancing your comfort but also saving money on your heating and cooling bills. This heat pump delivers both high-performance heating and cooling while reducing energy waste, making it a smart and sustainable choice for your home or office. Enjoy reliable climate control without compromising on environmental responsibility.
1. Max. COP: 5.56 2. Power Supply: 220V~240V/50Hz/1ph or 380V~420V/50Hz/3ph 3. Running Temp: -25℃~45℃ 4. Max. Heating Capacity: 6kw/9.5KW/12KW/16KW 5. Max. Cooling Capacity: 10.9KW 6. Multi-functions: Hot Water/House Heating/House Cooling
Model
CGK015V3L
CGK025V3L
CGK030V3L
CGK040V3L
CGK-025V3L
CGK-030V3L
CGK-040V3L
Power Supply / Refrigerant
V/Hz/Ph
220-240/50/1 - R32
380-420/50/3 - R32
Max. Heating Capacity (1)
kW
6
9.5
12
16
9.5
12
16
C.O.P (1)
W/W
4.45
4.58
4.45
4.71
4.58
4.45
4.71
Heating Capacity Min./Max.(1)
kW
2.76
/
6
4.37
/
9.5
5.52
/
12
7.36
/
16
4.37
/
9.5
5.52
/
12
7.36
/
16
Heating Power Input Min./Max.(1)
W
496
/
1348
763
/
2074
992
/
2697
1250
/
3397
763
/
2074
992
/
2697
1250
/
3397
C.O.P Min./Max.(1)
W/W
4.45
/
5.56
4.58
/
5.73
4.45
/
5.56
4.71
/
5.89
4.58
/
5.73
4.45
/
5.56
4.71
/
5.89
Max. Heating Capacity(2)
kW
5.8
9.1
11.5
15.4
9.1
11.5
15.4
C.O.P (2)
W/W
3.60
3.71
3.60
3.82
3.71
3.60
3.82
Heating Capacity Min./Max.(2)
kW
2.65
/
5.76
4.20
/
9.12
5.30
/
11.52
7.07
/
15.36
4.20
/
9.12
5.30
/
11.52
7.07
/
15.36
Heating power input Min./Max.(2)
W
627
/
1618
964
/
2489
1254
/
3236
1579
/
4076
964
/
2489
1254
/
3236
1579
/
4076
C.O.P Min./Max.(2)
W/W
3.56
/
4.23
3.66
/
4.35
3.56
/
4.23
3.77
/
4.47
3.66
/
4.35
3.56
/
4.23
3.77
/
4.47
Max. Cooling Capacity(3)
kW
5.5
8.7
10.9
14.6
8.7
10.9
14.6
E.E.R (3)
W/W
3.50
3.60
3.50
3.70
3.60
3.50
3.70
Cooling Capacity Min./Max.(3)
kW
2.52
/
5.47
3.99
/
8.66
5.03
/
10.94
6.71
/
14.59
3.99
/
8.66
5.03
/
10.94
6.71
/
14.59
Cooling Power Input Min./Max.(3)
W
608
/
1852
935
/
2849
1215
/
3704
1531
/
4666
935
/
2849
1215
/
3704
1531
/
4666
E.E.R Min./Max.(3)
W/W
2.95
/
4.14
3.04
/
4.26
2.95
/
4.14
3.13
/
4.39
3.04
/
4.26
2.95
/
4.14
3.13
/
4.39
Max. Cooling Capacity(4)
kW
3.9
6.2
8.6
10.4
6.2
8.6
10.4
E.E.R(4)
W/W
2.52
2.59
2.62
2.66
2.59
2.62
2.66
Cooling Capacity Min./Max.(4)
kW
1.80
/
3.92
2.85
/
6.20
3.97
/
8.64
4.80
/
10.44
2.85
/
6.20
3.97
/
8.64
4.80
/
10.44
Cooling Power Input Min./Max.(4)
W
494
/
1559
760
/
2399
1090
/
3440
1245
/
3929
760
/
2399
1090
/
3440
1245
/
3929
E.E.R Min./Max.(4)
W/W
2.51
/
3.65
2.58
/
3.75
2.51
/
3.65
2.66
/
3.86
2.58
/
3.75
2.51
/
3.65
2.66
/
3.86
Rated Current
A
6.5
9.9
12.9
16.3
4.4
5.7
7.2
Max Power Input
kW
2.0
3.0
3.9
4.9
3.0
3.9
4.9
Max Current
A
9.4
14.4
18.7
23.6
6.3
8.3
10.4
Fuse or circuitbreakerer
A
16A
20A
25A
32A
13A
13A
16A
Compressor
Type - Quantity/System
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Fan
Quantity
1
1
1
1
1
1
1
Airflow
m3/h
1500
2500
3000
3500
2500
3000
3500
Rated power
W
60
80
100
120
80
100
120
Water Side Heat Exchanger
Type
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Water Pressure Drop
kPa
14
18
20
21
18
20
21
Piping Connection
Inch
G3/4"
G1"
G1"
G1"
G1"
G1"
G1"
Allowable Water Flow
Min./Rated./Max.
L/S
0.18
0.29
0.48
0.28
0.45
0.76
0.36
0.57
0.96
0.48
0.76
1.27
0.28
0.45
0.76
0.36
0.57
0.96
0.48
0.76
1.27
Noise Level
dB(A)
49
56
59
60
56
59
60
Net Dimension(L×D×H)
mm
990*375*655
1110*475*810
1110*475*810
1110*475*960
1110*475*810
1110*475*810
1110*475*960
Packing Dimension(L×D×H)
mm
1070*405*800
1200*540*970
1200*540*970
1200*540*1120
1200*540*970
1220*540*970
1200*540*1120
Net Weight
Kg
59
80
88
98
80
88
98
Gross Weight
Kg
80
108
116
126
108
116
126
Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
(2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
(3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;
(4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃;
Lower GWP
The new refrigerant gas R32 helps our DC inverter heat pumps operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
Increased Efficiency
With maximum COP 5.95, our ERP A+++ R32 EVI DC inverter heat pumps charge and recirculate more efficiently than DC inverter heat pumps of other refrigerants. They consume less energy, and can therefore help families reduce energy bills.
Smarter Technology
The CAREL controller is able to record temperatures unaided using sensors that record the surrounding conditions. With the WIFI online monitoring, customers will enjoy contactless support from our customer service center no matter where they are. Our R32 EVI DC inverter heat pumps are also featured with more intelligent protections.
Super Low Noise
In addition to brushless DC inverter fans, SPRSUN R32 DC inverter heat pumps adopt reinforced sound reduction measures such as the dual shock absorption by Panasonic Compressor. The sound levels start as low as 42 dBA, making itself the quietest system in our DC inverter lineup.
Guaranteed Safety
The refrigerant R32 is considered to be environment friendly, but improper handling and storage might lead to potential safety issues. All of this can be avoid by using SPRSUN R32 DC inverter heat pumps, since they are designed with anti-explosion measures to guarantee the safety.
Shipping & Returns Policy
Free Express Shipping on All orders within the USA