SPRSUN R32 ClimaPro Series - 20KW/22KW EVI DC Inverter Air Souce Heat Pumps
Recommended Accessories
ACiQ Heavy Duty Wall Brackets
$197.06
John D. "Great service! Highly recommend."
Jane S. "Saved $50 on my order."
Mike T. "Fast and reliable support."
1. Max. COP: 5.95/5.81
2. Power Supply: 220V~240V/50Hz/1ph or 380V~420V/50Hz/3ph
3. Running Temp: -25℃~45℃
4. Max. Heating Capacity: 20KW/22KW
5. Max. Cooling Capacity: 18.2KW/20.1KW
6. Multi-functions: Hot Water/House Heating/House Cooling
Experience renewable heating with the SPRSUN R32 ClimaPro Series - 20KW/22KW EVI DC Inverter Air Source Heat Pumps, designed to deliver high efficiency and consistent performance even in low temperatures. Equipped with a Panasonic rotary compressor, this system significantly improves heating efficiency, ensuring your home or business stays comfortable during the colder months. With an impressive heating capacity of up to 22KW and cooling capacity of up to 20.1KW, this heat pump offers versatile functionality for both heating and cooling needs.
The SPRSUN R32 ClimaPro Series features an intuitive 5-inch touch screen for easy control. The vibrant display allows you to effortlessly adjust temperatures and switch between modes, providing an all-in-one, convenient user experience. Whether you need efficient heating or cooling, this system combines advanced technology with ease of use to create a comfortable and energy-efficient environment.
This DC Inverter air source heat pump is ideal for anyone looking for a powerful and eco-friendly system. With its impressive capacity, high efficiency, and user-friendly controls, it’s the perfect choice for those looking to reduce energy costs while maintaining year-round comfort.
In addition, this low-temperature air source heat pump produces low noise and offers you a quiet environment, perfect for properties in cold areas or cold climates as it uses the outdoor air as its heat source in the winter and heat sink in the summer. Quote for SPRSUN EVI DC Inverter Air Source Heat Pumps now!
Model | CGK050V3L | CGK-050V3L | CGK060V3L | CGK-060V3L | ||||||||||
Power Supply / Refrigerant | V/Hz/Ph | 220-240/50/1 - R32 | 380-420/50/3 - R32 | 220-240/50/1 - R32 | 380-420/50/3 - R32 | |||||||||
Max. Heating Capacity (1) | kW | 20 | 20 | 22 | 22 | |||||||||
C.O.P (1) | W/W | 4.75 | 4.76 | 4.62 | 4.65 | |||||||||
Heating Capacity Min./Max.(1) | kW | 9.2 | / | 20 | 9.2 | / | 20 | 10.12 | / | 22 | 10.12 | / | 22 | |
Heating Power Input Min./Max.(1) | W | 1549 | / | 4211 | 1546 | / | 4202 | 1752 | / | 4762 | 1741 | / | 4731 | |
C.O.P Min./Max.(1) | W/W | 4.75 | / | 5.94 | 4.76 | / | 5.95 | 4.62 | / | 5.78 | 4.65 | / | 5.81 | |
Max. Heating Capacity(2) | kW | 19.2 | 19.2 | 21.1 | 21.1 | |||||||||
C.O.P (2) | W/W | 3.85 | 3.81 | 3.70 | 3.60 | |||||||||
Heating Capacity Min./Max.(2) | kW | 8.83 | / | 19.20 | 8.83 | / | 19.20 | 9.72 | / | 21.12 | 9.72 | / | 21.12 | |
Heating power input Min./Max.(2) | W | 1957 | / | 5053 | 1953 | / | 5042 | 2214 | / | 5714 | 2199 | / | 5677 | |
C.O.P Min./Max.(2) | W/W | 3.80 | / | 4.51 | 3.81 | / | 4.52 | 3.70 | / | 4.39 | 3.72 | / | 4.42 | |
Max. Cooling Capacity(3) | kW | 18.2 | 18.2 | 20.1 | 20.1 | |||||||||
E.E.R (3) | W/W | 3.73 | 3.69 | 3.59 | 3.50 | |||||||||
Cooling Capacity Min./Max.(3) | kW | 8.39 | / | 18.24 | 8.39 | / | 18.24 | 9.23 | / | 20.06 | 9.23 | / | 20.06 | |
Cooling Power Input Min./Max.(3) | W | 1897 | / | 5783 | 1893 | / | 5771 | 2146 | / | 6540 | 2132 | / | 6498 | |
E.E.R Min./Max.(3) | W/W | 3.15 | / | 4.42 | 3.16 | / | 4.43 | 3.07 | / | 4.30 | 3.09 | / | 4.33 | |
Max. Cooling Capacity(4) | kW | 14.4 | 14.4 | 15.8 | 15.8 | |||||||||
E.E.R(4) | W/W | 2.80 | 2.77 | 2.69 | 2.62 | |||||||||
Cooling Capacity Min./Max.(4) | kW | 6.62 | / | 14.40 | 6.62 | / | 14.40 | 7.29 | / | 15.84 | 7.29 | / | 15.84 | |
Cooling Power Input Min./Max.(4) | W | 1702 | / | 5371 | 1699 | / | 5360 | 1925 | / | 6075 | 1913 | / | 6036 | |
E.E.R Min./Max.(4) | W/W | 2.68 | / | 3.89 | 2.69 | / | 3.90 | 2.61 | / | 3.79 | 2.62 | / | 3.81 | |
Rated Current | A | 20.1 | 8.9 | 22.8 | 10.0 | |||||||||
Max Power Input | kW | 6.1 | 6.1 | 6.9 | 6.9 | |||||||||
Max Current | A | 29.2 | 12.9 | 33.0 | 14.5 | |||||||||
Fuse or circuitbreakerer | A | 40A | 20A | 40A | 20A | |||||||||
Compressor | Type - Quantity/System | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | |||||||||
Fan | Quantity | 2 | 2 | 2 | 2 | |||||||||
Airflow | m3/h | 5000 | 5000 | 5500 | 5500 | |||||||||
Rated power | W | 200 | 200 | 210 | 210 | |||||||||
Water Side Heat Exchanger | Type | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger | |||||||||
Water Pressure Drop | kPa | 23 | 23 | 25 | 25 | |||||||||
Piping Connection | Inch | G1" | G1" | G1" | G1" | |||||||||
Allowable Water Flow | Min./Rated./Max. | L/S | 0.60 | 0.96 | 1.59 | 0.60 | 0.96 | 1.59 | 0.66 | 1.05 | 1.75 | 0.66 | 1.05 | 1.75 |
Noise Level | dB(A) | 61 | 61 | 62 | 62 | |||||||||
Net Dimension(L×D×H) | mm | 1110*475*1355 | 1110*475*1355 | 1110*475*1355 | 1110*475*1355 | |||||||||
Packing Dimension(L×D×H) | mm | 1200*540*1510 | 1200*540*1510 | 1200*540*1510 | 1200*540*1510 | |||||||||
Net Weight | Kg | 124 | 124 | 124 | 124 | |||||||||
Gross Weight | Kg | 161 | 161 | 161 | 161 | |||||||||
Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃; | ||||||||||||||
(2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃; | ||||||||||||||
(3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃; | ||||||||||||||
(4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/W |
The information in this document is just for reference. Since the continuous improvement and control in the production process, the information contained in this document may be subject to change. Please refer to the nameplate on the machine for model specifications.
The new refrigerant gas R32 helps our DC inverter heat pumps operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
With maximum COP 5.95, our ERP A+++ R32 EVI DC inverter heat pumps charge and recirculate more efficiently than DC inverter heat pumps of other refrigerants. They consume less energy, and can therefore help families reduce energy bills.
The CAREL controller is able to record temperatures unaided using sensors that record the surrounding conditions. With the WIFI online monitoring, customers will enjoy contactless support from our customer service center no matter where they are. Our R32 EVI DC inverter heat pumps are also featured with more intelligent protections.
Super Low Noise
In addition to brushless DC inverter fans, SPRSUN R32 DC inverter heat pumps adopt reinforced sound reduction measures such as the dual shock absorption by Panasonic Compressor. The sound levels start as low as 42 dBA, making itself the quietest system in our DC inverter lineup.
The refrigerant R32 is considered to be environment friendly, but improper handling and storage might lead to potential safety issues. All of this can be avoid by using SPRSUN R32 DC inverter heat pumps, since they are designed with anti-explosion measures to guarantee the safety.
Free Express Shipping on All orders within the USA
30 Day Free Returns on all orders
Request A Quote
Buy 3+ and SAVE up to $5,000! Code: BULK
Buy 10 or more and get upto $15,000 OFF!! Code: BIG BULK
$197.06
Build the perfect HVAC unit
Get up to 40% OFF on your next system with our custom tool!
Build Your SYSTEMLatest from HVAC & More
What Size Mini Split Do I Need?
If you’re considering buying a mini split for your home, your first question might be, “What siz...
Who Makes Pioneer Mini Split?
Are you curious about who makes Pioneer mini split systems? Pioneer mini split is competitiv...
How to Install a Mini Split
Looking to learn how to install a mini split yourself? While you can look at a video on how to ...