SPRSUN R290 Greenergy Series - 6-15KW Ultra-quiet DC Inverter Air Sour — Home Selection
BUY IN BULK AND GET 10% OFF NOW Code "BULK"
BUY IN BULK AND GET 10% OFF NOW Code "BULK"
Call Button
Call Now Get up to $200 OFF when you call! Ends in 10:00

Customer Reviews

John D. "Great service! Highly recommend."

Jane S. "Saved $50 on my order."

Mike T. "Fast and reliable support."

SPRSUN R290 Greenergy Series - 6-15KW Ultra-quiet DC Inverter Air Source Heat Pumps 


1. High Energy Efficiency and Multiple Modes for Comfortable Use;
2. Running Temp: -25℃~45℃
3. Max. Outlet Water Temperature: 75℃;
4. Built-in Water Pump;
5. Super Quiet: the noise level is as low as 40db(A);
6. Support WIFI Control and SG Ready;

 

 

 

Product Description

SPRSUN's latest innovation, the R290 ultra-quiet DC inverter air source heat pump, fulfills users' needs for efficient heating, cooling, and domestic hot water all in one unit. It features an innovative "Silent Compartment" design, allowing its operating noise level to be as low as 40dB(A), and even quieter at night! This series of heat pumps uses full inverter compressors, enabling efficient heating and providing users with a quiet and comfortable home experience. Additionally, they support WiFi remote control and SG-ready functionality. This means you can control your home's temperature and hot water with your phone anytime, anywhere. With the SG-ready function, the unit can communicate with the power grid to reduce household electricity consumption during peak periods and save on electricity bills.


Super Quiet The Greenergy series air source heat pumps support ultra-quiet operation as low as 40dB(A). The new "silent compartment" noise reduction technology ensures that your home life is not disturbed by noise.
User-friendly Design
The heat pumps support one-click switching of multiple modes. The brushless DC variable frequency control technology allows for more precise temperature control and a more comfortable user experience.


Intelligent Control and Connectivity
SPRSUN has developed a smart control system that allows for remote access through different platforms, including PCs and mobiles. This system enables cloud data synchronization and on-the-go heat pump management from anywhere, anytime.
ERP A+++ Performance
This heat pump uses high-efficiency DC inverter compressors and motors, with a high system efficiency and stable operation, saving energy costs for users.
 


The Specification of R290 ultra-quiet DC inverter air source heat pump
Model
CGK020V4P-B CGK030V4P-B CGK040V4P-B CGK-030V4P-B CGK-040V4P-B CGK-050V4P-B
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 220-240/50/1 220-240/50/1 380-420/50/3 220-240/50/1 380-420/50/3
Max. Heating Capacity (A7℃/W35℃) kW 6.1 9.1 12 9.1 12 15.2
C.O.P (A7℃/W35℃) W/W 4.4 4.2 3.9 4.2 3.9 3.9
Heating Capacity Min./Max.(A7℃/W35℃) kW 2.20 / 6.10 3.15 / 9.10 4.35 / 12.00 3.15 / 9.10 4.35 / 12.00 5.60 / 15.20
Heating Power Input Min./Max.(A7℃/W35℃) W 441 / 1386 626 / 2167 885 / 3073 626 / 2167 885 / 3073 1125 / 3900
C.O.P Min./Max.(A7℃/W35℃) W/W 4.4 / 4.99 4.2 / 5.03 3.90 / 4.92 4.2 / 5.03 3.90 / 4.92 3.90 / 4.98
Max. Heating Capacity(A7℃/W45℃) kW 6.30 8.60 11.2 8.60 11.2 14.5
C.O.P (A7℃/W45℃) W/W 3.60 3.52 3.28 3.52 3.28 3.23
Heating Capacity Min./Max.(A7℃/W45℃) kW 2.01 / 6.30 2.90 / 8.60 4.00 / 11.20 2.90 / 8.60 4.00 / 11.20 5.40 / 14.50
Heating power input Min./Max.(A7℃/W45℃) W 522 / 1750 757 / 2443 1071 / 3415 757 / 2443 1071 / 3415 1427 / 4489
C.O.P Min./Max.(A7℃/W45℃) W/W 3.60 / 3.85 3.52 / 3.83 3.28 / 3.74 3.52 / 3.83 3.28 / 3.74 3.23 / 3.78
Max. Cooling Capacity(A35℃/W18℃) kW 5.70 7.04 10.0 7.04 10.0 13.6
E.E.R (A35℃/W18℃) W/W 3.48 3.43 3.40 3.43 3.40 3.28
Cooling Capacity Min./Max.(A35℃/W18℃) kW 1.82 / 5.70 2.64 / 7.04 3.81 / 10.00 2.64 / 7.04 3.81 / 10.00 5.20 / 13.60
Cooling Power Input Min./Max.(A35℃/W18℃) W 463 / 1638 677 / 2052 1003 / 2941 677 / 2052 1003 / 2941 1402 / 4146
E.E.R Min./Max.(A35℃/W18℃) W/W 3.48 / 3.93 3.43 / 3.90 3.40 / 3.80 3.43 / 3.90 3.40 / 3.80 3.28 / 3.71
Max. Cooling Capacity(A35℃/W7℃) kW 4.45 5.63 7.2 5.63 7.2 10.2
E.E.R(A35℃/W7℃) W/W 2.87 2.66 2.62 2.66 2.62 2.60
Cooling Capacity Min./Max.(A35℃/W7℃) kW 1.53 / 4.45 2.10 / 5.63 3.58 / 7.20 2.10 / 5.63 3.58 / 7.20 4.52 / 10.20
Cooling Power Input Min./Max.(A35℃/W7℃) W 443 / 1551 612 / 2117 1213 / 2748 612 / 2117 1213 / 2748 1520 / 3923
E.E.R Min./Max.(A35℃/W7℃) W/W 2.87 / 3.45 2.66 / 3.43 2.62 / 2.95 2.66 / 3.43 2.62 / 2.95 2.60 / 2.97
Max Power Input  kW 3.00 4.00 5.00 4.00 5.00 6.30
Max Current A 14.35 19.14 23.92 8.44 10.55 13.29
Wire diameter mm² 4.0 4.0 6.0 2.5 2.5 4.0
Fuse or circuitbreakerer  A 20A 25A 32A 13A 16A 20A
Compressor
Type - Quantity/System
Brand HIGHLY HIGHLY HIGHLY HIGHLY HIGHLY HIGHLY
Refrigerant / Suggested Input Kg R290/0.50 R290/0.75 R290/0.90 R290/0.75 R290/0.90 R290/1.20
Fan Type / DC DC DC DC DC DC
Quantity / 1 1 1 1 1 2
Airflow m3/h 2500 3000 3500 3000 3500 5000
Rated Fan Speed RPM 900 900 900 900 900 900
Rated power W 116 116 116 116 116 116*2
Water Side Heat Exchanger Type / Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Water Pressure Drop kPa 18 20 23 20 23 25
Piping Connection Inch G1" G1" G1" G1" G1" G1"
Pump model / APM25-9-130SPWM1 APM25-9-130SPWM1 APM25-9-130SPWM1 APM25-9-130SPWM1 APM25-9-130SPWM1 APF25-12-130E FPWM1
Max Water Pump Head m
9

9

9

9

9

12
Allowable Water Flow Min./Rated./Max. L/S 0.18 0.29 0.49 0.27 0.43 0.72 0.36 0.57 0.96 0.27 0.43 0.72 0.36 0.57 0.96 0.45 0.73 1.21
Noise Level (Power Power) dB(A) 53 55 58 54 57 60
Moisture Resistance / IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Net Dimension(L×D×H) mm 1053*475*755 1110*475*810 1110*475*960 1110*475*810 1110*475*960 1110*475*1355
Carton packing Dimension(L×D×H)
mm 1115*505*910 1165*505*960 1165*505*1100 1165*505*960 1165*505*1100 1165*505*1520
Splint packing Dimension(L×D×H)
mm 1150*530*920 1200*530*970 1200*530*1120 1220*530*970 1200*530*1120 1200*530*1510
Net Weight kg 90 106 120 106 120 151
Carton gross Weight kg 102 119 133 119 133 166
Splint  gross Weight kg 122 142 156 142 156 188
Container Loading Capacity (20/40HQ) number 44 / 96 44 / 92 44 / 92 44 / 92 44 / 92 22 / 48
Operation Ambint Temp.(℃) -25~45
Operation water Temp.(℃) 10~70(DHW)
Operation water Temp.(℃) 10~70(Heating)
Operation water Temp.(℃) 12~30(Cooling)
Note:  (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
            (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
              (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;
            (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃;

Free Express Shipping on All orders within the USA

Read Our Shipping Policy Here

30 Day Free Returns on all orders

Read about our Returns Policy Here

Ask a Question?

Skip to content

SPRSUN R290 Greenergy Series - 6-15KW Ultra-quiet DC Inverter Air Source Heat Pumps

by SPRSUN
SKU
In stock | ETA: to
$0.00

Notify me when back in stock

SPRSUN R290 Greenergy Series - 6-15KW Ultra-quiet DC Inverter Air Source Heat Pumps
$0.00
Product successfully added to your cart!

SPRSUN R290 Greenergy Series - 6-15KW Ultra-quiet DC Inverter Air Source Heat Pumps Reviews

Build the perfect HVAC unit

Get up to 40% OFF on your next system with our custom tool!

Build Your SYSTEM

Latest from HVAC & More

  • Mini Split Cost vs Central Air: Comparing Cooling Options for Your Home

  • How to Add Refrigerant to Mini Split: A Quick Guide for Techs

  • What is the Major Advantage of Mini-Split Air-Conditioning Systems? Space-Saving Efficiency Explained

Read about HVAC

FREE EXPRESS SHIPPING

Process orders in 1 business day

Stress Free Returns

2 Year Returns

Primum Quality

Top Tier Products, Even Better Customer Care

5 Year Warranty

We Believe In Our Products & Our Team