SPRSUN Big Heating Capacity 32KW R410A Monoblock Full Inverter Air Source Heat Pump
Recommended Accessories
ACiQ Heavy Duty Wall Brackets
$197.06
John D. "Great service! Highly recommend."
Jane S. "Saved $50 on my order."
Mike T. "Fast and reliable support."
The SPRSUN Big Heating Capacity 32KW R410A Monoblock Full Inverter Air Source Heat Pump is a versatile and high-efficiency solution designed to provide reliable heating, cooling, and hot water for both residential and commercial spaces. With a remarkable COP of 5.53, this heat pump offers outstanding energy efficiency, ensuring that you get the most out of every unit of electricity used. Its full inverter technology provides precise control over heating and cooling capacities, offering a customizable, energy-saving solution for your home or business.
Operating in a wide temperature range of -20℃ to 45℃, the SPRSUN Big Heating Capacity 32KW R410A Monoblock Full Inverter Air Source Heat Pump is capable of heating up to 32KW, while also offering a cooling capacity of up to 28.6KW. This flexibility ensures optimal comfort in all seasons, providing warm, efficient heating in the winter and cool relief during the summer months. Its multi-functional capabilities extend beyond basic heating and cooling, as it can also supply hot water, making it an all-in-one solution for your heating needs.
With the use of R410A refrigerant, the SPRSUN Big Heating Capacity 32KW R410A Monoblock Full Inverter Air Source Heat Pump is both eco-friendly and highly efficient, offering a sustainable alternative to traditional heating and cooling systems. Designed for long-term, dependable performance, this heat pump is powered by a 380V~420V/50Hz/3ph power supply, making it ideal for large homes, commercial buildings, or other high-demand applications.
1. Max. COP: 5.53
2. Power Supply: 380V~420V/50Hz/3ph
3. Running Temp: -20℃~45℃
4. Max. Heating Capacity: 32KW
5. Max. Cooling Capacity: 28.6KW
6. Multi-functions: Hot Water/House Heating/House Cooling
SPRSUN‘s R401A inverter air source heat pump uses a variable speed compressor, which regulates its output to increase or decrease its speed to precisely match the building's heat demand requirements as the outside air temperature varies. R410A heat pump will lower its output when the demand is low, reducing the amount of power used.
R410A heat pump features a high heating capacity of 32KW and a cooling capacity of 28.6KW. Hence, it operates well even in large properties. It can heat hot water and the house, as well as cool the house when the weather is hot.
Model | CGK-080V2 | CGK-100V2 | ||||||
Power Supply / Refrigerant | V/Hz/Ph | 380-420/50/3 - R410A | 380-420/50/3 - R410A | |||||
Max. Heating Capacity (1) | kW | 26 | 32 | |||||
C.O.P (1) | W/W | 4.52 | 4.42 | |||||
Heating Capacity Min./Max.(1) | kW | 11.96 | / | 26 | 14.72 | / | 32 | |
Heating Power Input Min./Max.(1) | W | 2117 | / | 5752 | 2664 | / | 7240 | |
C.O.P Min./Max. (1) | W/W | 4.52 | / | 5.65 | 4.42 | / | 5.53 | |
Max. Heating Capacity (2) | kW | 24.4 | 30.1 | |||||
C.O.P (2) | W/W | 3.62 | 3.43 | |||||
Heating Capacity Min./Max.(2) | kW | 11.24 | / | 24.44 | 13.84 | / | 30.08 | |
Heating power input Min./Max.(2) | W | 2618 | / | 6759 | 3295 | / | 8507 | |
C.O.P Min./Max. (2) | W/W | 3.62 | / | 4.29 | 3.54 | / | 4.20 | |
Max. Cooling Capacity (3) | kW | 23.2 | 28.6 | |||||
E.E.R (3) | W/W | 3.51 | 3.32 | |||||
Cooling Capacity Min./Max.(3) | kW | 10.68 | / | 23.22 | 13.14 | / | 28.58 | |
Cooling Power Input Min./Max.(3) | W | 2538 | / | 7736 | 3194 | / | 9737 | |
E.E.R Min./Max. (3) | W/W | 3.00 | / | 4.21 | 2.93 | / | 4.12 | |
Max. Cooling Capacity (4) | kW | 18.33 | 22.6 | |||||
E.E.R (4) | W/W | 2.63 | 2.49 | |||||
Cooling Capacity Min./Max.(4) | kW | 8.43 | / | 18.33 | 10.38 | / | 22.56 | |
Cooling Power Input Min./Max.(4) | W | 2277 | / | 7185 | 2866 | / | 9043 | |
E.E.R Min./Max. (4) | W/W | 2.55 | / | 3.70 | 2.49 | / | 3.62 | |
Rated Current | A | 12.1 | 15.3 | |||||
Max Current | A | 17.60 | 22.15 | |||||
Compressor | Type - Quantity/System | Twin Rotary - 1 | Twin Rotary - 1 | |||||
Fan | Quantity | 2 | 1 | |||||
Airflow | m3/h | 7500 | 10000 | |||||
Rated power | W | 250 | 500 | |||||
Water Side Heat Exchanger | Type | Plate Heat Exchanger | Plate Heat Exchanger | |||||
Water Pressure Drop | kPa | 23 | 25 | |||||
Piping Connection | Inch | G1" | G1 1/4" | |||||
Allowable Water Flow | Min./Rated./Max. | L/S | 0.78 | 1.24 | 2.07 | 0.96 | 1.53 | 2.55 |
Noise Level | dB(A) | 62 | 63 | |||||
Net Dimension(L×D×H) | mm | 1237*480*1410 | 1000*1000*1855 | |||||
Net Weight | Kg | 200 | 300 | |||||
Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃; | ||||||||
(2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃; | ||||||||
(3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃; | ||||||||
(4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃. |
The ERP energy label gives an indication of energy efficiency in products. A rating system of A to G is used to rate the efficiency of products such as heat pumps. The ERP A+++ energy label, rated by TUV SUD, is the highest rating available. This rating indicates that The new DC inverter heat pumps from SPRSUN have been rated ERP A+++ our air source heat pumps have low energy consumption and a high coefficient with a maximum COP of 5.65 and SCOP of 4 88.of performance (COP). The highly energy-efficient DC inverter heat pumps use more than 30% less energy than other air source heat pumps.
Before the indoor temperature reaches the set value, the Panasonic rotary compressor delivers high levels of efficiency, enabling the unit to operate at high frequency so that it can heat water or provide house heating/cooling at a faster speed.
With Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level. SPRSUN Full Inverter Heat Pump Series can realize low noise running of 59dB(A) when testing at sound power, equivalent to 45dB when testing at 1 meter.
Mode 1 Central Hot Water: Constant Temperature, Sufficient Water Volume, 24-hour Instant Supply
Mode 2 Central Cooling: Water Cooled Air Conditioning, Soft Air Supply, Comfortable for Human Body.
Mode 3 Whole House Heating: Water Cycled Floor Heating, Well-distributed Heat Dissipation, Healthy & Energy Saving.
Mode 4 Hot Water + House Cooling: Meet the Requirements of Both Central Hot Water and Air Conditioning.
Mode 5 Hot Water + House Heating: Meet the Requirements of Both Central Hot Water and Room Heating.
Free Express Shipping on All orders within the USA
30 Day Free Returns on all orders
Request A Quote
Buy 3+ and SAVE up to $5,000! Code: BULK
Buy 10 or more and get upto $15,000 OFF!! Code: BIG BULK
$197.06
Build the perfect HVAC unit
Get up to 40% OFF on your next system with our custom tool!
Build Your SYSTEMLatest from HVAC & More
What Size Mini Split Do I Need?
If you’re considering buying a mini split for your home, your first question might be, “What siz...
Who Makes Pioneer Mini Split?
Are you curious about who makes Pioneer mini split systems? Pioneer mini split is competitiv...
How to Install a Mini Split
Looking to learn how to install a mini split yourself? While you can look at a video on how to ...