Summer Sale save $200 on your next order. Code: "Save200"
Summer Sale save $200 on your next order. Code: "Save200"
Call Button
CALL US Speak With Expert
(800)270-0086
Skip to content

Pioneer® Quad (4) Zone Quantum Series Outdoor Section 23.1 SEER2 Multi Split Inverter+ Air Conditioner & Heat Pump 230V

SKU YN040GMFI22M4E
In stock | ETA: to
Save $612.00
Original Price $3,180.00
Current Price $2,568.00

Notify me when back in stock

FREE EXPRESS SHIPPING

Process orders in 1 business day

Stress Free Returns

2 Year Returns

Primum Quality

Top Tier Products, Even Better Customer Care

5 Year Warranty

We Believe In Our Products & Our Team

Pioneer® Quad (4) Zone Quantum Series Outdoor Section 23.1 SEER2 Multi Split Inverter+ Air Conditioner & Heat Pump 230V


Overview

Get ultimate control with the Pioneer® Quad (4) Zone Quantum Series Outdoor Section! With its high SEER2 rating and multi split inverter, this unit efficiently cools and heats any outdoor space. Say goodbye to hot summers and cold winters with this 230V air conditioner and heat pump.

Summary

  • OUTDOOR SECTION ONLY for Quad (4) Zone Quantum/Free-Match Series
  • Ultra High Efficiency DC Inverter++ version
  • Cooling capacity: 36,000 BTU/H Nominal (Range: 8,789 MIN ~ 40,288 MAX) with 23.1 SEER2 / 10.6 EER2 efficiency
  • Heating capacity: 37,000 BTU/H Nominal (Range: 6,900 MIN ~ 46,624 MAX) with 9.6 HSPF2 efficiency
  • Voltage: 208~230 V, 60 Hertz, 1 Ph
  • Factory charged for up to 25’ line set per circuit
  • Whisper Quiet Operation

[[REFRIGERANT]]

Technical Information

Certifications

Pioneer Mini Split Certifications

Performance Data

  • Power Supply: 208~230V, 60Hz, 1Ph
  • Communication Protocol: Current Loop
  • Min-Max Load Attached: 24,000~48,000 BTU/h
  • Cooling Rated Capacity: 36,000 BTU/h
  • Cooling Capacity Range: 8,789~40,288 BTU/h
  • Cooling SEER2 (Ductless): 23.1 BTU/W.h
  • Cooling EER2 (Ductless): 10.6 BTU/W.h
  • Heating Rated Capacity: 37,000 BTU/h
  • Heating Capacity Range: 6,900~46,624 BTU/h
  • Heating HSPF2 (Ductless): 9.6 BTU/W.h
  • Refrigerant Type: R410a
  • Suitable Area: 1,200~1,600 Sq.F
  • Sound Level: 62.5 dB(A)
  • Net Dimensions (WDH): 37.2 x 16.2 x 31.8 Inches
  • Carton Dimensions (WDH): 42.8 x 19.6 x 34.8 Inches
  • Net / Gross Weight: 169 / 182 Lbs

 

Matching Indoor Models

Quad Zone Combinations

Rating Two Units Three units Four units  
Wall: 9 + 9 + 9 + 9 9 + 18 9 + 9 + 9 9 + 9 + 9 + 9  
Ducted: 9 + 9 + 9 + 9 9 + 24 9 + 9 + 12 9 + 9 + 9 + 12  
  12 + 12 9 + 9 + 18 9 + 9 + 9 + 18  
12 + 18 9 + 9 + 24 9 + 9 + 12 + 12
  12 + 24 9 + 12 + 12 9 + 9 + 12 + 18  
  18 + 18 9 + 12 + 18 9 + 12 + 12 + 12  
  18 + 24 9 + 18 + 18 12 + 12 + 12 + 12  
  24 + 24 12 + 12 + 12
 
    12 + 12 + 18    
    12 + 18 + 18    
12 + 12 + 24

9,000 BTU Compatible Units

  • Wall Mounted: WS009GMFI22HLE (30.3 x 11.8 x 21.8 inches)
  • Cassette: CB009GMFILCFHD (22.5 x 22.5 x 10.3 inches)
  • Concealed Ducted: RB009GMFILDFHD (27.5 x 25.0 x 8.3 inches)

12,000 BTU Compatible Units

  • Wall Mounted: WS012GMFI22HLE (31.5 x 13.2 x 21.7 inches)
  • Cassette: CB012GMFILCFHD (22.5 x 22.5 x 10.3 inches)
  • Floor-Console: FB012GMFILDFHE (27.5 x 23.6 x 8.3 inches)
  • Concealed Ducted: RB012GMFILDFHD (27.5 x 25.0 x 8.3 inches)

18,000 BTU Compatible Units

  • Wall Mounted: WS018GMFI22HLE (33.3 x 14.4 x 27.6 inches)
  • Cassette: CB018GMFILCFHD (22.5 x 22.5 x 10.3 inches)
  • Concealed Ducted: RB018GMFILDFHD (36.3 x 25.0 x 8.3 inches)
  • Flex mount: UB018GMFILCFHD (42.0 x 26.5 x 9.3 inches)

24,000 BTU Compatible Units

  • Wall Mounted: WS024GMFI22HLE (42.5 x 8.8 x 13.2 Inches)
  • Cassette: CB024GMFILDFHE (33 x 33 x 8 inches)
  • Concealed Ducted: RB024GMFILDFHD (43-3/8 x 30-1/2 x 9-3/4 inches)
  • Flex mount: UB024GMFILCFHD (42 x 26-1/2 x 9-1/4 inches)

Min. / Max. Loading

24,000 / 48,000 BTU/h.

Notes

Every indoor unit attached will operate at a random, self regulated capacity, based on the actual demand it measures from the zone it is serving (Between 30% to 100% of its rated capacity or OFF). Outdoor unit will also self regulate its output capacity, based on the total demand it reads from all of the simultaneously running indoor units at any given moment.

With multi split systems, the total demand from the outdoor unit, shall seldomly exceed 67% of the total available capacity of the combined indoor unit group due to load fluctuations. Although very seldom, if and when the total demand from the combined indoor group exceeds the rated capacity of the outdoor unit, the capacity of the each indoor unit will be annotated accordingly.

For high demand heating applications, max loading limits may need to be reduced by 10-15 % to avoid under-performance risks at some extreme conditions.

Manuals & Downloads

Free Express Shipping on All orders within the USA 

30 Day Free Returns on all orders

Ask a Question?