SPRSUN 39KW-200KW Ground Source Heat Pump Air Conditioner for House Heating & Cooling
Recommended Accessories
ACiQ Heavy Duty Wall Brackets
$197.06
John D. "Great service! Highly recommend."
Jane S. "Saved $50 on my order."
Mike T. "Fast and reliable support."
The SPRSUN 39KW-200KW Ground Source Heat Pump Air Conditioner for House Heating & Cooling provides a powerful and eco-friendly solution for residential heating and cooling.
This heat pump offers an impressive heating capacity range from 39KW to 200KW, making it ideal for large homes or multi-unit residential buildings. With efficient energy use and advanced ground-source technology, this unit is designed to deliver consistent comfort year-round, while significantly reducing energy costs.
Operating within a temperature range of -10℃ to 35℃, the SPRSUN 39KW-200KW Ground Source Heat Pump is capable of heating water to temperatures between 25℃ and 55℃ and cooling water to temperatures as low as 10℃, offering versatile climate control for your home. Whether you need heating during the winter or cooling during the summer, this system provides reliable performance across various seasons, ensuring your home remains comfortable all year long.
Running on a 380V~415V/50Hz/3ph power supply, the SPRSUN 39KW-200KW Ground Source Heat Pump is designed for high-demand residential applications. Its ground-source technology provides both efficient heating and cooling with minimal environmental impact. If you are looking for an energy-efficient, reliable, and versatile HVAC solution for a larger residential space, this heat pump is the perfect choice.
SPRSUN geothermal ground source heat pumps are designed for house heating and cooling (hot water/house heating functions available in other models) with COP up to 5.25. They have the following important features:
Closed Loop System;
Absorb heat from soil underground;
Source Side Temp: -10℃ to 35℃;
Setting range: heating 25℃~55℃; cooling 30℃~10℃;
Circulating water pump controlling;
Linkage ON/OFF function by external controlling system signal;
Electric heater back up;
Timer function;
Multiple protections
Rated working condition:
Cooling: source side inlet/outlet water temp: 30℃/35℃; load side inlet/outlet water temp: 12℃/7℃;
Heating: Source side inlet/outlet water temp: 15℃/10℃,
load side inlet/outlet water temp: 40℃/45℃ - CGS-36(HC); CGS-42(HC); CGS-52(HC); CGS-72(HC); CGS-95(HC)
load side inlet/outlet water temp: 15℃/55℃ - CGS-36; CGS-42; CGS-52 CGS-72; CGS-95
Model | CGS-36(HC) Heat & Cooling |
CGS-42(HC) Heat & Cooling |
CGS-52(HC) Heat & Cooling |
CGS-72(HC) Heat & Cooling |
CGS-95(HC) Heat & Cooling |
CGS-36 No Cooling |
CGS-42 No Cooling |
CGS-52 No Cooling |
CGS-72 No Cooling |
CGS-95 No Cooling |
|
Power Supply | V | 380V~415V/50Hz/3ph | 380V~415V/50Hz/3ph | 380V~415V/50Hz/3ph | |||||||
Refrigerant | R410A | R407C | R410A | ||||||||
Heating Capacity | KW | 39 | 46 | 56 | 76 | 100 | 39 | 48 | 56 | 76 | 100 |
Input Power of Heating | KW | 7.46 | 8.78 | 10.69 | 14.53 | 19.16 | 7.46 | 9.16 | 10.69 | 14.53 | 19.16 |
COP | 5.23 | 5.24 | 5.24 | 5.23 | 5.22 | 5.23 | 5.24 | 5.24 | 5.23 | 5.22 | |
Cooling Capacity | KW | 33.2 | 39.1 | 47.6 | 64.6 | 85 | / | / | / | / | / |
Input Power of Cooling | KW | 7.29 | 8.58 | 10.44 | 14.2 | 18.72 | / | / | / | / | / |
EER | 4.55 | 4.56 | 4.56 | 4.55 | 4.54 | / | / | / | / | / | |
Rated Current | A | 13.8 | 16.3 | 19.8 | 27 | 35.5 | 14.2 | 17.4 | 20.3 | 27.6 | 36.4 |
Max Current | A | 18.7 | 22 | 26.8 | 36.4 | 48 | 19.1 | 23.5 | 27.4 | 37.3 | 49.1 |
Water Flow of Load Side | L/h | 7452 | 8790 | 10700 | 14522 | 19108 | 7452 | 9172 | 10700 | 14522 | 19108 |
Water Flow of Source Side | L/h | 6781 | 8001 | 9741 | 13213 | 17378 | 6027 | 7421 | 8658 | 11745 | 15447 |
Water Pressure Drop | Kpa | ≤40 | ≤42 | ≤45 | ≤48 | ≤50 | ≤40 | ≤42 | ≤45 | ≤48 | ≤50 |
Net Weight | kg | 165 | 180 | 350 | 451 | 475 | 165 | 180 | 350 | 451 | 475 |
Gross Weight | kg | 185 | 200 | 370 | 471 | 495 | 185 | 200 | 370 | 471 | 495 |
Noise | db | 56 | 56 | 58 | 65 | 68 | 56 | 56 | 58 | 65 | 68 |
Pipe Size (Internal Thread) | mm | 32 | 32 | 50 | 50 | 65 | 32 | 32 | 50 | 50 | 65 |
Dimension | mm | 1040*600*1200 | 1240*840*1650 | 1040*600*1200 | 1240*840*1650 | ||||||
Packing Dimension | mm | 1090*705*1560 | 1090*705*1560 | 1040*640*1140 | 1300*900*1800 | 1090*705*1560 | 1040*640*1140 | 1300*900*1800 | |||
Compressor Model/Quantity | ZW54KWP*2 | ZW72KWP*2 | ZW54KWP*2 | ZW108KAE*2 | VR144KSE*2 | ZW54KWP*2 | ZW72KWP*2 | ZW83KWP*2 | ZW108KAE*2 | VR144KSE*2 |
Our ground source heat pumps use high quality components such as Copeland scroll compressor, Emerson thermal expansion valve, SANHUA 4-way valve, etc.
It is easy to install SPRSUN ground source heat pump as below:
We care every detail on what you need!
Super Low Noise: Fitted cut clothes for compressor and strong pads to avoid vibration
Anti-corrosion: Aluminum edging
Exellent Welding Guarantee No Leakage: Four-way valve welding protection
Energy Saving: 30mm thickness for insulation to prevent energy lost
User-friendly Design: Ram design using machine wire
Reliability of the Connection: Adopt automatic stamping machine from Taiwan
Related models are as below:
Free Express Shipping on All orders within the USA
30 Day Free Returns on all orders
Request A Quote
Buy 3+ and SAVE up to $5,000! Code: BULK
Buy $2000 and up and get a free Toolkit Code: TOOLKIT
$197.06
Build the perfect HVAC unit
Get up to 40% OFF on your next system with our custom tool!
Build Your SYSTEMLatest from HVAC & More
MRCOOL Warranty: How long is it and what does it cover?
MRCOOL mini splits are extremely popular, but what happens if yours needs a new part or if someth...
DuctlessAire vs MRCOOL
If you’re searching for the perfect mini split for your needs and exploring DuctlessAire vs MRCOO...
Does MRCOOL make ceiling cassette mini splits?
Does MRCOOL make ceiling cassette mini splits? The answer is yes. MRCOOL is a homeowner’s favorit...