Summer Sale save $200 on your next order. Code: "Save200"
Summer Sale save $200 on your next order. Code: "Save200"
Call Button
CALL US Speak With Expert
(800)270-0086
Skip to content

SPRSUN R290 Greenergy Pro Series - 9-12KW ERP A+++ DC Inverter Air Source Heat Pumps

by SPRSUN
SKU
In stock | ETA: to
Sold out
$0.00
Availability: Translation missing: en.general.icons.icon_check_circle icon Out of stock

Notify me when back in stock

BUSINESS INFORMATION

We are available 9am-10pm EST, 5 days a week. You can reach us at 800 270 0086. We are also available via live chat, email support@ahomeselection.com

Location: 38 Niagara Falls Blvd, Buffalo New York 14214, United States

FREE EXPRESS SHIPPING

Process orders in 1 business day

Stress Free Returns

2 Year Returns

Primum Quality

Top Tier Products, Even Better Customer Care

5 Year Warranty

We Believe In Our Products & Our Team

SPRSUN R290 Greenergy Pro Series - 9-12KW ERP A+++ DC Inverter Air Source Heat Pumps 


Product Description

SPRSUN 9KW R290 DC Inverter Air Source Heat Pumps Parameter

Model
CGK030V4P CGK040V4P CGK-030V4P CGK-040V4P
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R290 220-240/50/1 - R290 380-420/50/3 - R290 380-420/50/3 - R290
Max. Heating Capacity (A7℃/W35℃) kW 9.5 11.5 9.5 11.5
C.O.P (A7℃/W35℃) W/W 4.42 4.44 4.42 4.44
Heating Capacity Min./Max.(A7℃/W35℃) kW 4.37 / 9.50 5.29 / 11.50 4.37 / 9.50 5.29 / 11.50
Heating Power Input Min./Max.(A7℃/W35℃) W 778 / 2149 938 / 2590 778 / 2149 938 / 2590
C.O.P Min./Max.(A7℃/W35℃) W/W 4.42 / 5.61 4.44 / 5.64 4.42 / 5.61 4.44 / 5.64
Max. Heating Capacity(A7℃/W45℃) kW 8.9 10.7 8.9 10.7
C.O.P (A7℃/W45℃) W/W 3.64 3.77 3.64 3.77
Heating Capacity Min./Max.(A7℃/W45℃) kW 4.09 / 8.88 4.92 / 10.70 4.09 / 8.88 4.92 / 10.70
Heating power input Min./Max.(A7℃/W45℃) W 958 / 2439 1148 / 2834 958 / 2512 1148 / 3011
C.O.P Min./Max.(A7℃/W45℃) W/W 3.64 / 4.27 3.77 / 4.29 3.54 / 4.27 3.55 / 4.29
Max. Cooling Capacity(A35℃/W18℃) kW 8.4 10.2 8.4 10.2
E.E.R (A35℃/W18℃) W/W 3.53 3.66 3.53 3.66
Cooling Capacity Min./Max.(A35℃/W18℃) kW 3.88 / 8.44 4.67 / 10.16 3.88 / 8.44 4.67 / 10.16
Cooling Power Input Min./Max.(A35℃/W18℃) W 928 / 2389 1113 / 2775 928 / 2389 1113 / 2775
E.E.R Min./Max.(A35℃/W18℃) W/W 3.53 / 4.18 3.66 / 4.20 3.53 / 4.18 3.66 / 4.20
Max. Cooling Capacity(A35℃/W7℃) kW 7.5 9.0 7.5 9.0
E.E.R(A35℃/W7℃) W/W 2.90 2.92 2.90 2.92
Cooling Capacity Min./Max.(A35℃/W7℃) kW 3.45 / 7.50 4.14 / 9.00 3.45 / 7.50 4.14 / 9.00
Cooling Power Input Min./Max.(A35℃/W7℃) W 938 / 2586 1120 / 3082 938 / 2586 1120 / 3082
E.E.R Min./Max.(A35℃/W7℃) W/W 2.90 / 3.68 2.92 / 3.70 2.90 / 3.68 2.92 / 3.70
Max Power Input  kW 4.36 5.05 4.36 5.05
Max Current A 20.86 24.16 9.20 10.66
Wire diameter mm² 4.0 6.0 2.5 2.5
Fuse or circuitbreakerer  A 32A 32A 13A 16A
Compressor Type - Quantity/System
Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1
Fan Quantity
1 1 1 1
Airflow m3/h 3000 3500 3000 3500
Rated power W 100 120 100 120
Water Side Heat Exchanger Type
Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Water Pressure Drop kPa 20 21 20 21
Piping Connection Inch G1" G1" G1" G1"
Pump model / UPM4XLK 25-90 130 UPM4XLK 25-90 130 UPM4XLK 25-90 130 UPM4XLK 25-90 130
Max Water Pump Head m
9

9

9

9
Allowable Water Flow Min./Rated./Max. L/S 0.28 0.45 0.76 0.34 0.55 0.92 0.28 0.45 0.76 0.34 0.55 0.92
Sound power level(1m)
dB(A) 60.7 59.8 60.3 61.6
Net Dimension(L×D×H) mm 1110*475*810 1110*475*960 1110*475*810 1110*475*960
Carton packing Dimension(L×D×H)
mm 1165*505*960 1165*505*1100 1165*505*960 1165*505*1100
Splint packing Dimension(L×D×H)
mm 1200*530*970 1200*530*1120 1220*530*970 1200*530*1120
Net Weight kg 112 125 112 125
Carton gross Weight
kg 125 138 125 138
Splint  gross Weight kg 148 161 148 161
Operation Ambint Temp.(℃) -25~45
Operation water Temp.(℃) 10~70(DHW)
Operation water Temp.(℃) 10~70(Heating)
Operation water Temp.(℃) 12~30(Cooling)
Note:  (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
            (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
              (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;
            (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃;

The information in this document is just for reference. Since the continuous improvement and control in the production process, the information contained in this document may be subject to change. Please refer to the nameplate on the machine for model specifications.

 

1. CAREL Intelligent System

1) Intelligent monitoring. Real-time monitoring of all data and timely intervention when anomalies are detected
2) Intelligent defrosting
3) Intelligent touch screen operation
4) Intelligent control system
 

2. High Safety Performance

1) Use of well-known branded accessories with explosion-proof function to ensure safety. For example, Panasonic and Grundfos.
2) The creative original "safety compartment" structure design prevents leakage of refrigerant, making it more safe with a safety factor of class A.
 

3. Noise Reduction Technology

1) The CAREL system can be selected for different application scenarios on requirement to reduce noise and ensure a comfortable environment, such as day mode and night mode.
2) Self-developed all-round noise reduction, double-layer noise reduction of the compressor.

 

4. Energy Saving

1) Supports the highest level energy efficiency of A+++
2) Provides corresponding energy consumption settings for different clients requirements
3) SG function reduces energy bills

Free Express Shipping on All orders within the USA 

30 Day Free Returns on all orders

Ask a Question?