Summer Sale save $200 on your next order. Code: "Save200"
Summer Sale save $200 on your next order. Code: "Save200"
Call Button
CALL US Speak With Expert
(800)270-0086
Skip to content

SPRSUN R290 Greenergy Pro Series - 15-18KW ERP A+++ DC Inverter Air Source Heat Pumps

by SPRSUN
SKU
In stock | ETA: to
Sold out
$0.00
Availability: Translation missing: en.general.icons.icon_check_circle icon Out of stock

Notify me when back in stock

BUSINESS INFORMATION

We are available 9am-10pm EST, 5 days a week. You can reach us at 800 270 0086. We are also available via live chat, email support@ahomeselection.com

Location: 38 Niagara Falls Blvd, Buffalo New York 14214, United States

FREE EXPRESS SHIPPING

Process orders in 1 business day

Stress Free Returns

2 Year Returns

Primum Quality

Top Tier Products, Even Better Customer Care

5 Year Warranty

We Believe In Our Products & Our Team

SPRSUN R290 Greenergy Pro Series - 15-18KW ERP A+++ DC Inverter Air Source Heat Pumps 


1. Max. COP: 5.75
2. Power Supply / Refrigerant : 220-240/50/1 - R290;380-420/50/3 - R290
3. Running Temp: -25℃~45℃
4. Max. Heating Capacity: 15-18KW
5. Max. Cooling Capacity: 13-17KW
6. Multi-functions: hot water/heating/cooling/hot water+cooling/hot water+heating

 

Product Description

SPRSUN 18KW R290 DC Inverter Air Source Heat Pump Parame

 

Model
CGK050V4P CGK060V4P CGK-050V4P CGK-060V4P
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R290 220-240/50/1 - R290 380-420/50/3 - R290 380-420/50/3 - R290
Max. Heating Capacity (A7℃/W35℃) kW 15.5 18.5 15.5 18.5
C.O.P (A7℃/W35℃) W/W 4.42 4.14 4.42 4.14
Heating Capacity Min./Max.(A7℃/W35℃) kW 7.13 / 15.50 8.51 / 18.50 7.13 / 15.50 8.51 / 18.50
Heating Power Input Min./Max.(A7℃/W35℃) W 1241 / 3507 1523 / 4469 1241 / 3507 1523 / 4469
C.O.P Min./Max.(A7℃/W35℃) W/W 4.42 / 5.75 4.14 / 5.59 4.42 / 5.75 4.14 / 5.59
Max. Heating Capacity(A7℃/W45℃) kW 14.1 17.7 14.1 17.7
C.O.P (A7℃/W45℃) W/W 3.71 3.62 3.71 3.62
Heating Capacity Min./Max.(A7℃/W45℃) kW 6.49 / 14.11 8.13 / 17.67 6.49 / 14.11 8.13 / 17.67
Heating power input Min./Max.(A7℃/W45℃) W 1486 / 3799 1913 / 5334 1486 / 3989 1913 / 5334
C.O.P Min./Max.(A7℃/W45℃) W/W 3.71 / 4.37 3.31 / 4.25 3.54 / 4.37 3.31 / 4.25
Max. Cooling Capacity(A35℃/W18℃) kW 13.4 16.8 13.4 16.8
E.E.R (A35℃/W18℃) W/W 3.60 3.51 3.60 3.51
Cooling Capacity Min./Max.(A35℃/W18℃) kW 6.16 / 13.40 7.72 / 16.78 6.16 / 13.40 7.72 / 16.78
Cooling Power Input Min./Max.(A35℃/W18℃) W 1440 / 3721 1855 / 4780 1440 / 3721 1855 / 4780
E.E.R Min./Max.(A35℃/W18℃) W/W 3.60 / 4.28 3.51 / 4.16 3.60 / 4.28 3.51 / 4.16
Max. Cooling Capacity(A35℃/W7℃) kW 11.5 14.5 11.5 14.5
E.E.R(A35℃/W7℃) W/W 2.75 2.82 2.75 2.82
Cooling Capacity Min./Max.(A35℃/W7℃) kW 5.29 / 11.50 6.67 / 14.50 5.29 / 11.50 6.67 / 14.50
Cooling Power Input Min./Max.(A35℃/W7℃) W 1405 / 4182 1821 / 5142 1405 / 4182 1821 / 5142
E.E.R Min./Max.(A35℃/W7℃) W/W 2.75 / 3.77 2.82 / 3.66 2.75 / 3.77 2.82 / 3.66
Max Power Input  kW 6.80 7.83 6.80 7.83
Max Current A 32.54 37.46 14.35 16.52
Wire diameter mm² 6.0 6.0 4.0 4.0
Fuse or circuitbreakerer  A 40A 50A 20A 25A
Compressor Type - Quantity/System
Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1
Fan Quantity
2 2 2 2
Airflow m3/h 5000 5500 5000 5500
Rated power W 200 210 200 210
Water Side Heat Exchanger Type
Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Water Pressure Drop kPa 23 25 23 25
Piping Connection Inch G1" G1" G1" G1"
Pump model / UPM10L 25-105  130 UPM10L 25-105  130 UPM10L 25-105  130 UPM10L 25-105  130
Max Water Pump Head m
10.5

10.5

10.5

10.5
Allowable Water Flow Min./Rated./Max. L/S 0.46 0.74 1.23 0.55 0.88 1.47 0.46 0.74 1.23 0.55 0.88 1.47
Sound power level(1m)
dB(A) 62.1 63.2 61.6 61.1
Net Dimension(L×D×H) mm 1110*475*1355 1110*475*1355 1110*475*1355 1110*475*1355
Carton packing Dimension(L×D×H)
mm 1165*505*1520 1165*505*1520 1165*505*1520 1165*505*1520
Splint packing Dimension(L×D×H)
mm 1200*530*1510 1200*530*1510 1200*530*1510 1200*530*1510
Net Weight kg 145 147 145 147
Carton gross Weight
kg 160 172 160 172
Splint  gross Weight kg 182 184 182 184
Operation Ambint Temp.(℃) -25~45
Operation water Temp.(℃) 10~70(DHW)
Operation water Temp.(℃) 10~70(Heating)
Operation water Temp.(℃) 12~30(Cooling)
Note:  (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
            (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
              (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;
            (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, 

 

The information in this document is just for reference. Since the continuous improvement and control in the production process, the information contained in this document may be subject to change. Please refer to the nameplate on the machine for model specifications.

1. CAREL Intelligent System

1) Intelligent monitoring. Real-time monitoring of all data and timely intervention when anomalies are detected
2) Intelligent defrosting
3) Intelligent touch screen operation
4) Intelligent control system

2. High Safety Performance

1) Use of well-known branded accessories with explosion-proof function to ensure safety. For example, Panasonic and Grundfos.
2) The creative original "safety compartment" structure design prevents leakage of refrigerant, making it more safe with a safety factor of class A.

3. Noise Reduction Technology

1) The CAREL system can be selected for different application scenarios on requirement to reduce noise and ensure a comfortable environment, such as day mode and night mode.
2) Self-developed all-round noise reduction, double-layer noise reduction of the compressor.

4. Energy Saving

1) Supports the highest level energy efficiency of A+++
2) Provides corresponding energy consumption settings for different clients requirements
3) SG function reduces energy bills