Summer Sale save $200 on your next order. Code: "Save200"
Summer Sale save $200 on your next order. Code: "Save200"
Call Button
CALL US Speak With Expert
(800)270-0086
Skip to content

SPRSUN R410A Icefield-S Series - 9.6KW EVI DC Inverter Split Air Source Heat Pump

by SPRSUN
SKU
In stock | ETA: to
Sold out
$0.00
Availability: Translation missing: en.general.icons.icon_check_circle icon Out of stock

Notify me when back in stock

BUSINESS INFORMATION

We are available 9am-10pm EST, 5 days a week. You can reach us at 800 270 0086. We are also available via live chat, email support@ahomeselection.com

Location: 38 Niagara Falls Blvd, Buffalo New York 14214, United States

FREE EXPRESS SHIPPING

Process orders in 1 business day

Stress Free Returns

2 Year Returns

Primum Quality

Top Tier Products, Even Better Customer Care

5 Year Warranty

We Believe In Our Products & Our Team

SPRSUN R410A Icefield-S Series - 9.6KW EVI DC Inverter Split Air Source Heat Pump 


 

1. Max. COP: 5.56
2. Power Supply: 220V~240V/50Hz/1ph
3. Running Temp: -25℃~45℃
4. Max. Heating Capacity: 9.6KW
5. Max. Cooling Capacity: 7.9KW
6. Multi-functions: Hot Water/House Heating/House Cooling

 

 

Features 

SPRSUN EVI DC Inverter Split Air Source Heat Pump Water Heater functions equally well with a traditional gas boiler, and yet it costs minimal electricity and has little influence on the planet. This EVI air to water heat pump are designed for domestic hot water, room heating and cooling in areas with cold climates or lowest ambient temperature of -25℃. It has a maximum COP of 5.56 and a power supply of 220V~240V/50Hz/1ph. It reaches a maximum heating capacity of 9.6KW and a maximum cooling capacity of 7.9KW and yet produces super low noise.

 

 

Model
CGK030V2LS CGK050V2LS CGK060V2LS
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R410A 220-240/50/1 - R410A 220-240/50/1 - R410A
Max. Heating Capacity (1) kW 9.6 16.8 18.8
C.O.P (1) W/W 4.45 4.48 4.39
Heating Capacity Min./Max. (1) kW 4.416 / 9.6 7.728 / 16.8 8.648 / 18.8
Heating Power Input Min./Max. (1) W 794 / 2157 1380 / 3750 1576 / 4282
C.O.P Min./Max. (1) W/W 4.45 / 5.56 4.48 / 5.60 4.39 / 5.49
Max. Heating Capacity (2) kW 9.0 15.8 17.7
C.O.P (2) W/W 3.60 3.58 3.40
Heating Capacity Min./Max. (2) kW 4.15 / 9.02 7.26 / 15.79 8.13 / 17.67
Heating power input Min./Max. (2) W 982 / 2535 1707 / 4406 1949 / 5032
C.O.P Min./Max. (2) W/W 3.56 / 4.23 3.58 / 4.26 3.51 / 4.17
Max. Cooling Capacity (3) kW 7.9 13.9 15.6
E.E.R (3) W/W 3.50 3.48 3.30
Cooling Capacity Min./Max. (3) kW 3.65 / 7.94 6.39 / 13.90 7.15 / 15.55
Cooling Power Input Min./Max. (3) W 919 / 2688 1598 / 4672 1825 / 5335
E.E.R Min./Max. (3) W/W 2.95 / 3.97 2.97 / 4.00 2.91 / 3.92
Max. Cooling Capacity (4) kW 6.3 11.1 12.4
E.E.R (4) W/W 2.62 2.61 2.48
Cooling Capacity Min./Max. (4) kW 2.91 / 6.32 5.09 / 11.05 5.69 / 12.37
Cooling Power Input Min./Max. (4) W 831 / 2672 1444 / 4645 1649 / 5305
E.E.R Min./Max. (4) W/W 2.36 / 3.50 2.38 / 3.52 2.33 / 3.45
Rated Current A 10.3 17.9 20.5
Max Current A 14.97 26.02 29.71
Compressor Type - Quantity/System
Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1
Fan Quantity
1 2 2
Airflow m3/h 3000 5000 5500
Rated power W 100 200 210
Water Side Heat Exchanger Type
Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Water Pressure Drop kPa 20 23 25
Piping Connection Inch G1" G1" G1"
Allowable Water Flow Min./Rated./Max. L/S 0.29 0.46 0.76 0.50 0.80 1.34 0.56 0.90 1.50
Noise Level
dB(A) 59 62 63
Expansion Tank
L 5 5 5
Electric Heater
kW 3 6 6
Grundfos Inverter Pump

UPMGEO   25-85-130 UPMGEO   25-85-130 UPMGEO   25-85-130
Outdoor Unit Size(L×D×H) mm 1100*490*810 1100*490*1350 1100*490*1350
Indoor Unit Size(L×D×H) mm 550*325*650 550*325*650 550*325*650
Outdoor Unit Weight Kg 88 124 124
Indoor Unit Weight Kg 25 27 27
Note:  (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
           (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
           (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;
           (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃.

 

With 24-month long warranty, SPRSUN EVI Split DC Inverter Air Source Heat Pumps are designed for domestic hot water, room heating and cooling with lowest ambient temperature -25℃. They are featured with: 

  • Low Ambient Temperature (-25℃ to 45℃)

Use the Panasonic Enhanced Vapour Injection (EVI) Technology Rotary Compressor. Work stably in cold weather where lowest air temperature reaches -25℃.

  • Anti-freezing Protection

Split model design to better avoid freezing problem. Automatic anti-freezing protection by detecting system water temperature.

  • Improved Heating Efficiency

To save energy, it will automatically change to low frequency operation mode when temperature reaches set value.

  • Low Noise Operation

Thanks to the DC inverter brushless fans, our split EVI DC inverter heat pumps are operating with sound insulation measures to ensure you have a super low noise unit. 

  • Reduced Defrosting Time

When the unit needs defrosting, it will use high frequency operation, which greatly reduces the defrosting time.

 

 

Free Express Shipping on All orders within the USA 

30 Day Free Returns on all orders

Ask a Question?